VMEbus Modules
Models FlexTest® IIm/GT/SE Controller Hardware Installation
45
The rotary dipswitch settings for address C40 are shown below. Increment the
front panel dipswitch as required to complete ADDA II module addressing.
0
2
3
4
5
6
7
8
9
A
C
E
1F
S2
0
2
3
4
5
6
7
8
9
A
C
E
1F
S3
0
2
3
4
5
6
7
8
9
A
C
E
1F
On ADDA II
Front Panel
Front Panel VMEbus Modules
M
ODEL MODULE NAME FUNCTION
493.40 I/O Carrier Supports up to four mezzanine cards.
493.43 Multi-Box I/O The optional module allows multiple controllers to share a
master hardware synchronization clock and pass station
interlock state information between each other.
493.50 ADDA II This optional module supports up to four 8-channel A/D
(Model 493.55) or D/A (Model 493.56) mezzanine cards. This
module also supports the 8-channel DSPAD, 8-channel
Delta-Sigma A/D, and 4-channel Universal Encoder
mezzanine cards.
498.96-X Processor Provides an interface between the controller and an external
computer. The processor module also manages the plug-in
modules and transition panels.
498.71B GRES III Interfaces with a Remote Station Control (RSC) module and
temperature controllers.
I/O Carrier Mezzanine Cards (part 1 of 2)
M
ODEL MODULE NAME FUNCTION
493.14 Valve Driver Produces the control signal for a Series 252 Servovalve.
493.15 3–Stage Valve Driver Produces the control signal for a Series 256 or 257
Servovalve.
493.21B Universal Conditioner Processes the signals from either an AC or DC-type sensors.
493.25 Universal Conditioner Processes the signals from either an AC or DC-type sensors.
493.45 A/D Converts up to six external analog signals to digital signals for
use by the controller.
Comentários a estes Manuais