Specifications
Models FlexTest® IIm/GT/SE Controller Hardware Introduction
33
Specifications
Model 497.01 Specifications
P
ARAMETER SPECIFICATION
Environmental
Temperature
Relative humidity
For indoor use only
5ºC–40ºC (41ºF–104ºF)
10%–85%, relative, noncondensing
Power requirements +15 V at 6 A; -15 V at 6 A; +5 V at 6 A
(standard supply maximum output,
actual load depends on installed
modules)
Dimensions
Height
Width
Depth
17.8 cm (7 in)
48.3 cm (19 in)
31.1 cm (12.25 in)
Model 497.05 Specifications (part 1 of 2)
P
ARAMETER SPECIFICATION
Individual solenoid current
Total HSM solenoid current
2 A max
6 A max
Solenoid operating voltage 24 V DC or 115 V AC (switch
selectable)
497.05 power supply output
497.01 power supply output
+24 V at 7.5 A
+5 V at 6 A
+15 V at 6 A
-15 V at 6 A
Power requirements 90–132 V AC/180 - 264 V AC
47–63 Hz
500 W