MTS TestSuite
Multipurpose Simulated Testing User Guide
100-232-130 E be certain.
Vista de página 0
1 2 3 4 5 6 ... 99 100

Resumo do Conteúdo

Página 1 - MTS TestSuite

MTS TestSuiteMultipurpose Simulated Testing User Guide100-232-130 E be certain.

Página 2

Know your site number and system numberThe site number contains your company number and identifies your equipment type (such as material testingor sim

Página 4

• Keyboard enhancers• Print spoolers• Messaging applications1.3.0 If You Contact MTS by PhoneA Call Center agent registers your call before connecting

Página 5

• Write down any specific instructions.After you callMTS logs and tracks all calls to ensure that you receive assistance for your problem or request.

Página 6

2.0 Preface2.1.0 Before You BeginSafety first!Before you use your MTS product or system, read and understand the safety information provided with your

Página 7

CAUTION:Caution notices indicate the presence of a hazard with a low level of risk which, ifignored, could cause moderate or minor personal injury or

Página 8

Hypertext linksThe electronic document has many hypertext links displayed in a blue font. All blue words in the body text,along with all contents entr

Página 10

3.0 Controller Simulation OverviewTopics:•Controller Simulation...

Página 11

3.1.0 Controller SimulationSimulated controllerThe MTS TestSuite Controller Simulation Software CD includes the necessary software, controller files,

Página 12

If you run a simulated test and then want to run a different template, you must use the MPE application todisconnect from the controller (Controller &

Página 13 - 2.0 Preface

© 2013 MTS Systems Corporation. All rights reserved.Trademark InformationMTS and MTS TestSuite are registered trademarks of MTS Systems Corporation wi

Página 14

Low-Cycle Fatigue TemplatesDescriptionTemplateThis template complies with ASTM standardE606-04 and ASTM standard D3479/D 3479M-96ASTM LCF Strain(Reapp

Página 15 - MTS TestSuite 15

DescriptionTemplateto run Transition Tests, analyze the resultingdata, and provide reports of the results.This template complies with ASTM Standard E6

Página 16

DescriptionTemplateThis template complies with ASTM standardE647-08 and is designed to run FCG DCASTM E 647 FatigueCrack Growth DCPDPotential Drop (DC

Página 17 - MTS TestSuite 17

ToughnessThe following template is available for Toughness tests and analysis:Toughness TemplatesDescriptionTemplateThis template complies with ASTM E

Página 19 - 3.3.0 Fatigue Templates

4.0 Install Simulation SoftwareTopics:•Install MTS TestSuite Multipurpose Software...

Página 20

4.1.0 Install MTS TestSuite Multipurpose SoftwareTo install the MTS TestSuite Multipurpose software:1. Launch the MTS TestSuite self-extracting execut

Página 21 - 3.4.0 Fracture Templates

4.4.0 Install Controller Configuration FilesTo install controller configuration files:1. Start the MTS_TestSuite_Simulation self-extracting executable

Página 23

5.0 Running Simulation TestsTopics:•Simulated Controller Startup...

Página 24

Contents1.0 Technical Support 91.1.0 How to Get Technical Support...

Página 25 - MTS TestSuite 25

5.1.0 Simulated Controller Startup5.1.1.0 Start the MTS TestSuite Simulation SoftwareTo start the MTS TestSuite simulation software:1. Click Start >

Página 26

3. If any report template (.xltx) files from the import file already exist, you are prompted to Overwrite the filesor Cancel the import.If you already

Página 27

Precrack Parameter ValuesValue to Use for SimulationParameter25 mmPrecrack Final Crack Limit10 HzPrecrack Frequency0.100 unitlessPrecrack Load Ratio10

Página 28

Test Termination Parameter ValuesDescriptionParameterYesEnd on COD Limit1.2 mmCOD LimitNoEnd on Load LimitNoLoad LimitNoEnd on Displacement Limit50.00

Página 29 - 5.0 Running Simulation Tests

DescriptionParameterSpecify the number of cycles at whichprecrack activity stops.Precrack Cycle LimitSpecify the maximum stress intensity desiredat th

Página 30 - 5.2.1.0 Open The Test

5.2.2.7.0 Assign Precrack ValuesSpecify these parameters if the specimen was precracked on another load frame. When the precrackparameters are specifi

Página 31 - Simulation

Stress Intensity K ParametersDescriptionParameterSpecify the crack size value to use in thestress intensity (K) calculation.Crack SizeSpecify the load

Página 32

DescriptionParameterSpecify the modulus used for crack sizecalculations.Elastic ModulusSpecify the percent of load applied on thespecimen in order to

Página 33 - 5.2.2.3.0 Precrack Parameters

5. Typically, the activity will stop when a desired test termination parameter is achieved. In this case, reviewthe activity end result, and then clic

Página 34 - 5.2.2.4.0 CTOD Parameters

DescriptionParameteracceptable because of the higher frequenciesof some tests.Specify the voltage that is measured at thisload level. This parameter i

Página 35 - 5.2.2.8.0 Calculator

5.2.2.5.0 Data Storage Parameters...345.2.2.6.0 Test Termination Paramet

Página 36 - 5.2.3.0 Run the Test

• Crack Size Check Cycle - Data Acquisition shows data that was acquired during the crack size checkactivity.• Precrack Command - Data Acquisition sho

Página 37 - 5.2.3.4.0 Run Toughness Test

The variable definitions and mapping are transferred to your new test and can be modified to meet yourrequirements.Your original test is protected fro

Página 38

Channels by Time TableThe Channels by Time table lists all data points collected in arrays:• Time Array• Load Array• CTOD Array• Displacement ArrayCha

Página 39 - 5.2.4.0 View Test Results

Note:The test you open and use must correspond to the controller files that were copied to the workstationand the configuration that was selected when

Página 40 - 5.2.5.0 Perform Data Analysis

Value to Use for SimulationParameter10%Precrack Lower Least Squares FitPercentage90%Precrack Upper Least Squares FitPercentage1000000 countPrecrack Cy

Página 41 - 5.2.5.2.0 CTOD Analysis View

Value to Use for SimulationParameter100 countStore Every Nth Precrack Cycle10%FCG Lower Least Squares FitPercentage90%FCG Upper Least Squares FitPerce

Página 42 - 5.3.1.0 Open The Test

DescriptionParametersquares fit compliance determination. Thisparameter is not used for FCG DCPD tests.Specify the percentage of the measured loadrang

Página 43

DescriptionParameterSpecify the wave shape of the commandsignal.FCG Wave ShapeThe choices are True Sine or True Ramp.Typically, you use a True Ramp wa

Página 44

5.3.2.7.0 Data Storage Parameters PropertiesData Storage ParametersDescriptionParameterSpecify the percentage of precrack activitythat must complete b

Página 45 - 5.3.2.3.0 Precrack Parameters

Precrack ParametersDescriptionParameterSpecify the number of precrack cyclescompleted.Precrack CyclesCompletedSpecify the final crack size calculated

Página 46

5.3.4.0 View Test Results...525.3.4.1.0 View T

Página 47

Stress Intensity K ParametersDescriptionParameterSpecify the crack size value to use in thestress intensity (K) calculation.Crack SizeSpecify the load

Página 48

DescriptionParameterSpecify the modulus used for crack sizecalculations.Elastic ModulusSpecify the percent of load applied on thespecimen in order to

Página 49 - 5.3.2.10.0 Calculator

5.3.3.5.0 Enter Measured Crack SizesThe software automatically enters the crack sizes from the end of the precrack activity and the crack sizesfrom th

Página 50 - 5.3.3.0 Run the Test

5.3.5.0 Perform Data Analysis5.3.5.1.0 Start the Analyzer ApplicationTo start the analyzer application:1. On the Tools menu, click Fracture Analyzer A

Página 51 - 5.3.3.3.0 Precrack Specimen

5.3.5.2.0 Fatigue Crack Growth Analysis ViewThe template is preconfigured with a data view that conforms to the analysis portion of the ASTM standard.

Página 52 - 5.3.4.0 View Test Results

Validity Results TableThe Validity Results table includes the Display Name, Value, Modified Indicator, Original Value, and Calculation.The Display Nam

Página 53 - 5.3.5.0 Perform Data Analysis

5.4.0 Run the Simulated FCG DCPD Test5.4.1.0 Open The Test5.4.1.1.0 Open the Configuration File for the TestDetermine the controller configuration fil

Página 54

5. Reset the interlocks if needed and select the Low, then High, power buttons.6. Click Run to run the test.5.4.2.0 Set the FGC DCPD Test Parameters5.

Página 55

Value to Use for SimulationParameter0 1/mmNormalized K Gradient (C)0 kNFCG Measure Load LevelConstant Load Parameter ValuesValue to Use for Simulation

Página 56 - 5.4.1.0 Open The Test

5.4.2.3.0 Precrack ParametersThe following table lists the precrack parameters and their required values.Precrack ParametersDescriptionParameterSpecif

Página 57

5.5.2.2.0 JIC Parameter Values for Simulation...705.5.2.3.0 Precrack Parameters...

Página 58

5.4.2.5.0 Delta K Control Mode ParametersDelta K Control Mode ParametersDescriptionParameterSpecify the ratio of the minimum to maximumK applied to th

Página 59 - 5.4.2.3.0 Precrack Parameters

DescriptionParameterSpecify the cycle frequency of the commandsignal.FCG FrequencySpecify the wave shape of the commandsignal.FCG Wave ShapeThe choice

Página 60

DescriptionParameterSpecify Yes to end the test when the loadlimit is reached.Load LimitSpecify Yes to end the test when thedisplacement limit is reac

Página 61

Load P ParametersDescriptionParameterSpecify the crack size value to use in the loadcalculation.Crack SizeSpecify the stress intensity (K) value to us

Página 62 - 5.4.2.10.0 Calculator

Note:The Simulation CD includes a sample test that is based on the FCG DCPD template. To run thesample test, you must enter specific initial crack val

Página 63 - 5.4.3.0 Run the Test

2. Review the parameters.a) Click Yes to start with the parameters that are shown.b) Click No to return to the Main Menu and to change parameters.3. C

Página 64 - 5.4.3.3.0 Precrack Specimen

5.4.4.2.0 Fracture Test ResultsThe Test Results show the following information about the test run:• Variable Summary shows all the parameters and thei

Página 65 - 5.4.4.0 View Test Results

The recalculated values are updated in the currently open analysis run.A recommended procedure is to create a copy of your test and analysis definitio

Página 66 - 5.4.5.0 Perform Data Analysis

Crack Length, Min/Max K, Load by Cycles TableThe Crack Length, Min/Max K, Load by Cycles table provides values for the cycles in the FCG Cycle Arrayco

Página 67

ChartsThe charts provide visual indicators of the crack growth rate and the forces that affect the rate.• The da/dN vs. Delta K chart characterizes th

Página 68

5.6.3.5.0 Enter Measured Crack Sizes...935.6.3.6.0 End Simulation Test...

Página 69 - 5.5.1.0 Open The Test

Note:The test you open and use must correspond to the controller files that were copied to the workstationand the configuration that was selected when

Página 70

Value to Use for SimulationParameter0.1 unitlessPrecrack Load Ratio20%Precrack Lower Least Squares FitPercentage80%Precrack Upper Least Squares FitPer

Página 71

DescriptionParameter25%JIC Percent Unload4 kN/sJIC Reload Rate5 kN/sJIC Unload Rate30 HzJIC Data FrequencyDisplacement Control Mode Step ParametersDis

Página 72

DescriptionParameter30 HzJIC Data FrequencyData Storage ParametersData Storage Parameter ValuesValue to Use for SimulationParameter100 countStore Ever

Página 73 - 5.5.2.3.0 Precrack Parameters

Precrack ParametersDescriptionParameterSpecify the desired crack size to achieve inthe precrack activity. When the specifiedcrack size is achieved, th

Página 74 - 5.5.2.4.0 JIC Parameters

5.5.2.5.0 COD Mode ParametersCOD Mode ParametersDescriptionParameterSpecify the amount of force, in force units,to unload in both the unload and reloa

Página 75 - 5.5.2.5.0 COD Mode Parameters

DescriptionParameterdisplacement exceeds the specified limitvalue during the ramp segment of a step.When the limit trips, the JIC step immediatelyswit

Página 76

5.5.2.6.0 Displacement Mode ParametersDisplacement Mode ParametersDescriptionParameterSee description in COD mode parameters.JIC Absolute UnloadSpecif

Página 77

5.5.2.7.0 Data Storage ParametersData Storage ParametersDescriptionParameterSpecify the percentage of precrack activitythat must complete before data

Página 78

Precrack ParametersDescriptionParameterSpecify the number of precrack cyclescompleted.Precrack CyclesCompletedSpecify the final crack size calculated

Página 80 - 5.5.3.0 Run the Test

Stress Intensity K ParametersDescriptionParameterSpecify the crack size value to use in thestress intensity (K) calculation.Crack SizeSpecify the load

Página 81 - 5.5.3.3.0 Precrack Specimen

DescriptionParameterSpecify the modulus used for crack sizecalculations.Elastic ModulusSpecify the percent of load applied on thespecimen in order to

Página 82 - 5.5.4.0 View Test Results

5. Typically, the activity stops when a desired test termination parameter is achieved. In this case, reviewthe activity end result, and then click Cl

Página 83 - 5.5.5.0 Perform Data Analysis

2. Click Results.3. Click on the different tabs to view different types of results.5.5.4.2.0 Fracture Test ResultsThe Test Results show the following

Página 84

9. To calculate a variable for every cycle, select the variable name from the Additional Cycle VariableCalculations list and click the right arrow but

Página 85 - 5.6.1.0 Open The Test

Channels by Step TableThe Channels by Step table lists all data points collected in arrays:• Segment Type Array• Complete Load Data• Complete COD Data

Página 86

a. Click Browse and navigate to the location of the simulated test files. By default, the simulated test filesare saved to the C:\MTS TestSuite\TestAr

Página 87

Precrack ParametersPrecrack Parameter ValuesValue to Use for SimulationParameter25.4 mmPrecrack Final Crack Limit10 HzPrecrack Frequency0.1 unitlessPr

Página 88 - 5.6.2.3.0 Precrack Parameters

Value to Use for SimulationParameter1.35 mmKIC COD Upper LimitNoKIC Use Load Limit200000 NKIC Load Upper LimitNoKIC Use Displacement Limit50 mmKIC Dis

Página 89 - 5.6.2.4.0 KIC Parameters

DescriptionParameterSpecify the maximum stress intensity desiredat the end of precrack activity. The initialPrecrack Final MaximumKprecrack Maximum K

Página 90 - 5.6.2.8.0 Calculator

1.0 Technical Support1.1.0 How to Get Technical SupportStart with your manualsThe manuals supplied by MTS provide most of the information you need to

Página 91 - 5.6.3.0 Run the Test

DescriptionParameterSpecify the crack size that, if reached, stopsthe test.JIC Maximum Crack SizeSpecify the crack extension that, if reached,stops th

Página 92 - 5.6.3.3.0 Precrack Specimen

Load P ParametersDescriptionParameterSpecify the crack size value to use in the loadcalculation.Crack SizeSpecify the stress intensity (K) value to us

Página 93 - 5.6.4.0 View Test Results

4. Click Run on the control panel to start the crack size check. Optionally, if you want to review or changeparameters, click Return to Main Menu.5. W

Página 94 - 5.6.5.0 Perform Data Analysis

To suspend the activity after it starts, click Hold. When you suspend the activity, data collection stops andthe application attempts to hold at the m

Página 95

5.6.4.2.0 Fracture Test ResultsThe Test Results show the following information about the test run:• Variable Summary shows all the parameters and thei

Página 96

The recalculated values are updated in the currently open analysis run.A recommended procedure is to create a copy of your test and analysis definitio

Página 97 - MTS TestSuite 97

• Physical Stress Intensity• Net Section Stress• ValidityChannels by TimeThe Channels by Time table lists all data points collected in arrays:• KIC Ti

Página 98 - 98 MTS TestSuite

IndexAAdditional Cycle Variable Calculations 40, 53, 66, 83, 94Analysis Inputs table 41assign precrack values 35, 48, 62, 78, 90ASTMD3479/D 3479M-96 (

Página 99 - 100-232-130 E

precrack parameters 31, 33, 45, 59, 73, 88precrack specimen 37, 51, 64, 81, 92Rrestrictions 18results 39, 52, 65, 82, 93run FCG test 51, 64Ssimulation