Digital I/O Connections
Models FlexTest® IIm/GT/SE Controller Hardware FlexTest IIm Controller Connections
197
Digital inputs Digital inputs can be wired to allow the input from a switch contact, a relay
contact, or a logic signal.
All digital inputs are optically isolated at the Series 498 Digital I/O
transition module.
For example, an action defined in the can be selected, in the Station Setup
window’s Digital Input panel, as an Action.
The digital inputs are used by the Digital Input process in the MultiPurpose
TestWare application. They can also be monitored from the Station Manager
application.
You can use the Event-Action Editor window to define an action that occurs
in response to a digital input event. The defined action can then be selected
in the Station Setup window’s Digital Input panel.
Sixteen jumpers located on the Series 498 Digital I/O transition module allow
each input to be configured for a relay contact or logic signal.
Each digital input connector on the built-in Digital I/O Access panel (FlexTest
IIm) supports two channels.
Each digital input supports a differential TTL to +30 V DC signal or a
switch or relay contact switching the on-board 12 V supply.