Models FlexTest® IIm/GT/SE Controller Hardware
VMEbus Modules
Installation
44
Setting I/O Carrier
addresses
Use the dipswitch (S1) and rotary dipswitch (S2) on each I/O Carrier module to
set its address in accord with its installed chassis slot as follows:
Setting I/O Carrier
module addresses
The dipswitch settings for address C20 is shown below. Increment the rotary
dipswitch as required to complete I/O Carrier module addressing.
Setting GRES III
module addresses
The dipswitch settings for address C08 is shown below. Increment the rotary
dipswitch as required to complete GRES III module addressing.
Setting ADDA II
addresses
Use the onboard rotary dipswitches (S3, S2) and front panel rotary dipswitch on
each ADDA II module to set its address in accord with its installed chassis slot as
follows:
S
LOT
12345678910
ADDRESS
PPC C20 C22 C24 C26 C28 C2A C2C C2E
1 2 3 4 5 6 7 8
ON
C
2
0
2
3
4
5
6
7
8
9
A
C
E
1F
S1
S2
0
2
3
4
5
6
7
8
9
A
C
E
1F
S2
0
2
3
4
5
6
7
8
9
A
C
E
1F
S3
0
2
3
4
5
6
7
8
9
A
C
E
1F
S1
SLOT
12345678910
ADDRESS
PPC PPC C40 C41 C42 C43 C44 C4A C4C