Models FlexTest® IIm/GT/SE Controller Hardware
Connecting Interlock Signals to 407 Controllers
FlexTest GT Controller Connections
158
Multiple 407 Controller
interlock connections
The following figure shows how to cable interlocks for multiple Model 407
Controllers to the Model 493.10 Chassis (via its Model 493.74 HSM transition
module). Use the specified interlock cable (PN 056-455-0xx) to make these
connections for each Model 407 Controller station.
Run/Stop,
ActiveHigh
Hydraulic
Interlock,
ActiveLow
To
407
Controller
(Station 2)
To
493.74
HSM
Transition
Interlock Cable PN 056-455-0XX
Digital
I/O Connector
Jumper
Jumper
Jumper
Run/Stop,
ActiveHigh
Hydraulic
Interlock,
ActiveLow
To
407
Controller
(Station 1)
To
493.74
HSM
Transition
Interlock Cable PN 056-455-0XX
Digital
I/O Connector
Jumper
Jumper
Jumper