Models FlexTest® IIm/GT/SE Controller Hardware
Eurotherm Temperature Controller Connection
FlexTest SE Controller Connections
242
To add the resource, select the Miscellaneous tab and select 1 for temperature
controllers, then save the file. The application automatically adds the required
information in the proper syntax to the text in the hardware interface file.
Adding a temperature
control channel to the
station configuration
file
After updating the hardware interface file, you must add a temperature control
channel to the Controllers station configuration file.
To do this, use the Station Builder application to open the station configuration
file, and then add temperature controller input (Temp Control 1-Input) and output
(Temp Control 2-Output) resources to a Program w/Feedback type channel. This
creates a temperature control channel.
For detailed instructions, see “How to Program a Eurotherm Temperature
Controller” in the MTS 793 Control Software manual for more information.