Miscellaneous Conditioner Output Connections
Models FlexTest® IIm/GT/SE Controller Hardware FlexTest GT Controller Connections
167
Miscellaneous Conditioner Output Connections
The following table shows connector assignments for various MTS products you
can use with your the Model 493.10 Chassis.
Conditioning Sensors with Other MTS Products
MTS P
RODUCT SENSOR OUTPUT
Model 408.81 Testing Panel/
Model 408.82 DC Conditioner
Sensor output is available at the rear-panel connector J201
or J202.
Model 409.81C Temperature Controller
Temperature output (via an analog signal) is available at
rear-panel connector J1.
Model 448.82/85 Test Controller with
Model 448.21/22 AC and DC Conditioners
Sensor output is available at rear-panel connector J335.
Ensure sensor conditioners are set as follows:
X1: 2&3
X2: 2&3
Model 458.10/20 MicroConsole with Model
458.11/12/13/14 AC and DC Controllers
Sensor output is available at the MicroConsole rear-panel
connector Jx03. Connector Jx03 represents the module
location (J100–J600).
MicroConsole jumper Jx00 should be set to 1&2 (standard
setting).