Specifications
Models FlexTest® IIm/GT/SE Controller Hardware Introduction
29
FT IIm standard
configurations
• 4, 6, 8, 12, or 16 channels of control
• 16 inputs and 16 outputs of user DIO
• Per channel resources:
– One valve driver output
– One D/A output
– One A/D input
– One AC Conditioned input
– Two DC conditioned inputs
Console The FlexTest IIm Controller is available in a full-bay (vertical) console, a table-
top console, or a roll-around console.
Note The larger (full-bay) consoles can also accommodate rack-mount
scopes, x-y recorders, and so forth.
Customization A standard FlexTest IIm system can be customized for specific test requirements.
In these cases, the standard hardware and software can be changed to
accommodate a specific customer requirement.