Models FlexTest® IIm/GT/SE Controller Hardware
J49 Auxiliary Power
FlexTest SE Controller Connections
234
Jumper plug required If connector J43 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug PN 100-057-245, or jumper pins: 1-2,
3-4.
J49 Auxiliary Power
See “J49 Auxiliary Power” on page 140.
CJ51 Box In
Connector J51 Box In allows the Model 493.02 chassis to receive clock,
hydraulic, and interlock signals from another Model 493.02 chassis.
J51 Connector Pin Assignments
P
IN NAME FUNCTION
1 +clk in +External clock input
2 hyd high in Hydraulic high input
3 reset in Interlock reset request input
4 signal return Signal return for optically isolated inputs
5 /intlk in Hydraulic interlock input
6 hyd low in Hydraulic low input
7 signal return Signal return for optically isolated inputs
8 master/slave in Master -/Slave select input
9 - clk in - External clock input
10 hyd hi return out Hydraulic high return output
11 reset return out Interlock reset return output
12 ground Signal ground
13 /intlk return out Hydraulic interlock return output
14 hyd low return out Hydraulic low return output
15 ground Signal ground