Model 494.44 Two-Station System Board
MTS FlexTest® Models 40/60/100/200 Controller Hardware FlexTest Controller Configurations
93
Cable specification To maintain EMC compliance, J28 A/B HSM cables must comply with the
following specifications:
Connector—9-pin type D male EMI connector.
Backshell—EMI metallized plastic or metal.
Proportional Control Cable—18 AWG, 2-conductor with foil shield drain wire
connected to conductive backshell.
Off/low/high Control Cable—18 AWG, 3-conductor with foil shield drain wire
connected to conductive backshell.