Model 494.16 VD/DUC Mezzanine Card
MTS FlexTest® Models 40/60/100/200 Controller Hardware Mezzanine Cards
161
Specifications–Model 494.16 Valve Driver Card
PARAMETER SPECIFICATION
Output Current 100 mA maximum per output (software configurable)
Valve Outputs per
Card
2
Dither
Frequency
Amplitude
1 Hz–4915.2 Hz (software adjustable)
0–5 V DC (software adjustable)
Valve Clamping Software configurable valve clamping setting
performs the following actions when a hydraulic
interlock occurs.
Disabled—Valve does not clamp. This is the
default action if the clamp entry is omitted.
Zero—Clamps the servovalve to zero. If valve
balance is used, it will clamp to this value.
Positive—Clamps the servovalve to positive
50% spool opening on a 2-stage valve driver,
50% outer-loop command on the 3-stage valve
driver.
Negative—Clamps the servovalve to negative
50% spool opening on a 2-stage valve driver,
50% outer-loop command on a 3-stage valve
driver.
Valve Balance
Offset
+/- 10 V DC (software adjustable)