Mts Multi-Pump Control Manager Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Mts Multi-Pump Control Manager. MTS Multi-Pump Control Manager User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Product Information

be certain.mSupervisor and Basic Connection Interface (BCI)Multi-Pump Control Manager (MPCM)Product Information100-249-603 A

Página 2 - Publication information

Multi-Pump Control Manager10General Safety PracticesSafetyYou should receive training on this system or a similar system to ensure a thorough knowledg

Página 3 - Contents

General Safety PracticesMulti-Pump Control Manager Safety11Have first aid available Accidents can happen even when you are careful. Arrange your opera

Página 4

Multi-Pump Control Manager12General Safety PracticesSafetyUse appropriatelysized fusesWhenever you replace fuses for the system or supply, ensure that

Página 5 - Introduction

General Safety PracticesMulti-Pump Control Manager Safety13Know the causes ofunexpected actuatormotionsThe high force and velocity capabilities of MTS

Página 6 - Intended Use

Multi-Pump Control Manager14General Safety PracticesSafety

Página 7 - Specifications

Placement of ComponentsMulti-Pump Control Manager Installation15InstallationThe Multi-Pump Control Manager (MPCM) allows you to operate up to eight Hy

Página 8 - Mark for Canada

Multi-Pump Control Manager16Spacing RequirementsInstallationSpacing RequirementsThe front of the enclosure requires 65 cm (25.6 in) minimum of clearan

Página 9

Set HPU to Remote Operation for use with the MPCMMulti-Pump Control Manager Operation17OperationThis section deals with operation of the Multi-Pump Co

Página 10 - General Safety Practices

Multi-Pump Control Manager18SetupOperationNote Perform the following steps on the MPCM Supervisor.7. If not already displayed, press the Unit button t

Página 11

Startup and Main ScreenMulti-Pump Control Manager Operation19Startup and Main ScreenNote The following screen images may be from the 4 or 8 HPU versio

Página 12

Copyright information © 2011 MTS Systems Corporation. All rights reserved.Trademark information MTS and SilentFlo are registered trademarks of MTS Sys

Página 13 - Do not use RF

Multi-Pump Control Manager20SystemOperationSystemThe System screen provides an overview of the status of the entire hydraulic system. The RUN and PRES

Página 14

SystemMulti-Pump Control Manager Operation21Item Name Description1 System gauges: Flow/Pressure/TemperatureSystem gauges. The parameters of these gaug

Página 15 - Installation

Multi-Pump Control Manager22SystemOperation4 Module indicatorsColor scheme for the module icons is:• Dashed outline - not present• Gray with black bor

Página 16 - External Device Connections

UnitMulti-Pump Control Manager Operation23UnitThe Unit screen displays the HPU operational status. All available HPUs will be displayed in individual

Página 17 - Operation

Multi-Pump Control Manager24UnitOperationItem Name Description1 Faulted/Ready/Running/High Pressure/Alarm/Overtemp BypassIndicator. Indicates the vari

Página 18

UnitMulti-Pump Control Manager Operation253 Run/Stop/BypassPushbutton/Indicator. Pushbutton used to start and stop the HPU.Run - gray. black letters:

Página 19 - Startup and Main Screen

Multi-Pump Control Manager26UnitOperation8Unit HoursIndicator/Display: Indicates total running time of the HPU.9 Oil PressureIndicator/Display: Indica

Página 20

Status ScreenMulti-Pump Control Manager Operation27Status ScreenThe Status screen is displayed by pressing the Status button on the Main screen. The f

Página 21

Multi-Pump Control Manager28Status ScreenOperation3 Oil LevelIndicator. Used to indicate if the hydraulic fluid level is within acceptable limits.Oil

Página 22

Status ScreenMulti-Pump Control Manager Operation298StatusIndicator: Indicates the state of the associated module.Status - gray: Label.Not Present - l

Página 23

Multi-Pump Control Manager Contents3ContentsIntroduction 5Intended Use 6Specifications 7Safety 9General Safety Practices 9Installation

Página 24

Multi-Pump Control Manager30Status ScreenOperation14 Flow Demand IndicatorIndicates whether the user(s) are demanding a total flow demand that is with

Página 25

SetupMulti-Pump Control Manager Operation31SetupOn the Supervisor HMI, press the Setup button to display the System Setup screen.The following table d

Página 26

Multi-Pump Control Manager32StationOperationStationThe Station Flow Manager screen allows you to control the flow demand inputs.5 Serial Number, HMI S

Página 27 - Status Screen

Operating the HPU Locally or RemotelyMulti-Pump Control Manager Operation33Operating the HPU Locally or RemotelyThe HPU can be operated locally using

Página 28

Multi-Pump Control Manager34How to Clean the MPCMOperationRemote operation Note Perform the following steps on the MPCM Supervisor. 1. Configure each

Página 29

Setting Up System Run On Demand (ROD)Multi-Pump Control Manager Appendix35AppendixContents Setting Up System Run On Demand (ROD) 35Run On Demand De

Página 30

Multi-Pump Control Manager36Run On Demand Detailed ExampleAppendix7. Check the Off Delay.If necessary, press the associated value pushbutton to change

Página 31 - °C, LPM - black

Run On Demand Detailed ExampleMulti-Pump Control Manager Appendix37An example is shown below. In the example Module Flow is set at 30 gpm, Minimum Flo

Página 32

Multi-Pump Control Manager38Run On Demand Detailed ExampleAppendix

Página 34 - How to Clean the MPCM

Multi-Pump Control Manager4Contents

Página 35 - Appendix

mMTS Systems Corporation14000 Technology DriveEden Prairie, Minnesota 55344-2290 USAToll Free Phone: 800-328-2255(within the U.S. or Canada)Phone: 952

Página 36

Multi-Pump Control Manager Introduction5IntroductionThe Multi-Pump Control Manager (MPCM) product family consists of a Basic Connection Interface (BCI

Página 37 - Flow buer

Multi-Pump Control Manager6Intended UseIntroductionNote MTS can provide the BCI without the Supervisor and dedicated PC. In this case, the BCI commons

Página 38

SpecificationsMulti-Pump Control Manager Introduction7SpecificationsParameter SpecificationTemperature 5ºC–40ºC (41ºF–104ºF)Humidity 5–85%, non-conden

Página 39

Multi-Pump Control Manager8SpecificationsIntroductionNote Electrical connections must be made by qualified personnel and conform to local codes and r

Página 40

General Safety PracticesMulti-Pump Control Manager Safety9SafetyGeneral Safety PracticesThe Multi-Pump Control Manager (MPCM) product family consists

Comentários a estes Manuais

Sem comentários