Test Track Vehicle
Installing the Transducer
Test Track Vehicle
Equipment required This procedure requires one person. To install the SWIFT 40A or SWIFT 40T
sensor, you will need the following equipment:
Hub adapter (see next figure)
Modified rim (see next figure)
Anti-rotate assembly (including customer-supplied mounting arm)
Small set of hex-head wrenches (both English and metric)
Tube bender for the anti-rotate bar
Tube cutter
Metric socket head drive set (up to 14 mm) with extension
5/16-18 UNC tap
Molykote g-n paste (MTS part number 011-010-207)
Bolts
For SWIFT 40A Transducer
44 size M10 X 1.5 mm (inner hub and outer ring)
4 size M8 X 1.25 mm
4 size M5 X 0.8 mm
Lug nuts
For SWIFT 40T Transducer
24 size M10 X 1.5 mm
20 size M14 X 2.0 mm
4 size M8 X 1.25 mm
4 size M5 X 0.8 mm
Lug nuts
Torque wrenches, capable of the following ranges:
28–54 N•m (20–40 lbf•ft),
81–156 N•m (60-115 lbf•ft);
7 N•m (60 lbf •in)
Cables (transducer and BNC, plus customer-supplied from transducer
interface to data recorder)
Tie wraps
Data recorder
12 V power supply (for example, a car battery)