Precrack Parameter Values
Value to Use for SimulationParameter
25 mmPrecrack Final Crack Limit
10 HzPrecrack Frequency
0.100 unitlessPrecrack Load Ratio
10%Precrack Lower Least Squares Fit
Percentage
90%Precrack Upper Least Squares Fit
Percentage
1000000 countPrecrack Cycle Limit
0.348 kN/mm^1.5Precrack Final Maximum K
The following table lists the COD (Crack Opening Displacement) parameter values.
COD Parameter Values
Value to Use for SimulationParameter
CODControl Mode
0.03 mm/secRamp Rate
The following table lists the data storage parameter values.
Data Storage Parameter Values
Value to Use for SimulationParameter
0%Precrack Save Percent Limit
100Store Every Nth Precrack Cycle
20 HzCTOD Data Frequency
100 NDelta Force
The following table lists the test termination parameter values.
32 MTS TestSuite
5.0 Running Simulation Tests
Comentários a estes Manuais