Road and Track Vehicles
SWIFT 10 MC Sensors Installing the Transducer
73
Note Some data acquisition systems, power systems, and alternators may
introduce electrical noise spikes to the battery and cabling. The TI
electronics should always be used with the cleanest power supply
possible. To reduce the likelihood of noise spikes from the data recorder,
we suggest running the power cables in parallel, as shown in the
following diagrams. If this does not remove the noise spikes, separate
batteries may be required.
The data recorder should also be connected to the battery negative terminal.
(See the following figures.)
Suggested Grounding for a single TI Box
Suggested Grounding for a Multiple TI Boxes
3. Secure the TI box so that it will not move during data collection.
Note If the TI box is not properly secured, it can dislodged from the vehicle.
4. Cover the J4 I/O and J5 USB connectors to protect the connectors from
contamination.
5. Turn on the TI
Press and hold the Power switch until the indicator lights. All other
indicators will light until initialization is complete and then turn off. Only
the Power indicator should remain lit.
12 Vdc
Transducer Interface
S10-25
Data Recorder
12 Vdc
Transducer Interface
Transducer Interface
Data Recorder
S10MC-26